RM Solar S Class 20 Pro Bedienerhandbuch Seite 66

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 88
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 65
65
Section 4 - In Roof Frame Installation
Mounting The Flashings
At this point measure diagonally across the panels. The two measurements should be the same to
ensure the panels are square. A must equal B.
Mount the wooden latts supplied down the sides (and middle is using 2 or more panels) of the
panels using the 3 x large wood screws supplied (5x110mm). The wooden latts should be positioned
200mm from the bottom of the panels and should screw to the battens with a screw at the top middle
and bottom. The latts require pilot holes to prevent splitting.
The latts are tapered and the 90mm end goes to the top of collector array with the 95mm end going
to the bottom.
A
B
Seitenansicht 65
1 2 ... 61 62 63 64 65 66 67 68 69 70 71 ... 87 88

Kommentare zu diesen Handbüchern

Keine Kommentare